FM200 Cylinders Have Excellent Heat And Corrosion Resistance

Product Description:

our summary about FM200 (HFC-227ea, or heptafluoropropane) and its usage in fire suppression systems is quite accurate and comprehensive. Let me expand on this topic by delving deeper into the specifics of high-temperature resistant FM200 cylinders, their design, and the considerations necessary for their proper use in high-temperature environments.

High-Temperature Resistance in FM200 Cylinders

Material Selection

The material selection for FM200 cylinders is critical, especially in high-temperature applications. As mentioned, standard FM200 cylinders are typically made of carbon steel, which is known for its strength and ability to withstand the high internal pressures of the compressed gas. However, for environments where the ambient temperature can exceed the typical operating range of -40°C to +50°C, more robust materials are required. Stainless steel, for example, offers superior thermal resistance and corrosion resistance, making it a preferred choice for high-temperature applications

2. Stainless steel cylinders can handle higher temperatures without the risk of degradation or failure, ensuring the integrity of the fire suppression system.

Thermal Insulation

Thermal insulation is another key factor in enhancing the high-temperature resistance of FM200 cylinders. Insulating the cylinders can prevent direct heat exposure, which is crucial in maintaining the internal pressure within safe limits. Common insulating materials include ceramic fibers, mineral wool, and foam insulations. These materials not only reduce heat transfer but also provide additional protection against physical damage. Properly insulated cylinders can operate effectively even in environments with significant temperature fluctuations, ensuring that the fire suppression system remains functional and safe.

Pressure Relief Valves

Pressure relief valves are essential components in any pressurized system, and they play a particularly critical role in high-temperature applications. These valves are designed to open automatically when the internal pressure exceeds a predetermined safe level, thereby preventing the cylinder from overpressurizing and potentially rupturing. In high-temperature environments, the risk of pressure buildup is higher, so the pressure relief valves must be carefully selected and calibrated to ensure they function reliably under these conditions. Regular testing and maintenance of these valves are also crucial to ensure their continued effectiveness.

Specialized Design Considerations

For extreme high-temperature applications, specialized design considerations may be necessary. Some manufacturers offer custom solutions tailored to specific environmental conditions. These can include:

  • Reinforced Cylinder Walls: Thicker walls can provide additional strength and resistance to high temperatures.
  • Heat Shielding: External heat shields can be installed to further protect the cylinders from radiant heat sources.
  • Temperature Monitoring Systems: Integrated temperature sensors can continuously monitor the ambient and internal temperatures, providing real-time data and alerts if the temperature exceeds safe limits.
  • Cooling Systems: Active cooling systems can be employed to maintain the temperature within the desired range, ensuring optimal performance of the fire suppression system.

Consultation and Compliance

When selecting and installing FM200 cylinders for high-temperature applications, it is essential to consult with the manufacturer or a fire protection specialist. They can provide expert guidance on the following aspects:

  • Appropriate Cylinder Type: Ensuring that the chosen cylinders are suitable for the specific temperature range and environmental conditions.
  • Installation Practices: Proper installation techniques to minimize heat exposure and ensure the system’s reliability.
  • Maintenance Requirements: Regular inspection and maintenance schedules to keep the system in optimal condition and comply with safety standards.

Compliance with relevant safety standards and regulations is also crucial. For example, the National Fire Protection Association (NFPA) Standard 2001 provides guidelines for the design, installation, and maintenance of clean agent fire suppression systems, including those using FM200. Adhering to these standards ensures that the system meets the necessary safety and performance criteria.

Conclusion

In summary, high-temperature resistant FM200 cylinders are essential for applications where the ambient temperature can exceed the standard operating range. By using enhanced materials, thermal insulation, reliable pressure relief valves, and specialized design considerations, these cylinders can effectively protect sensitive equipment in high-temperature environments. Consulting with experts and adhering to safety standards are key steps in ensuring the system’s reliability and effectiveness.

Technical Parameters:

Diameter280-400mm
Pressure10.0MPa≤p<100.0MPa
InstallationEasy To Install
Storage MediumFM200, Hfc-227ea, Novec 1230 Etc.
TrademarkXingjin / OEM
Place of OriginGuangzhou, Guangdong, China
Mini Order20 Set
ColorRed
CertificateGSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1
Production Capacity3000 Sets Per Week

Applications:

The FM200 Cylinder is a new product that is in excellent condition. The cylinder is designed to release a clean agent that extinguishes fires in a matter of seconds. The FM200 Cylinder is an excellent choice for fire protection in various application occasions and scenarios. The following are some of the application occasions and scenarios that the FM200 Cylinder is ideal for:

  • Computer rooms and data centers
  • Telecommunication facilities
  • Museums and art galleries
  • Archives and record storage facilities
  • Power generation facilities
  • Medical facilities
  • Oil and gas facilities
  • Chemical processing plants

The FM200 Cylinder is a reliable and effective fire protection solution that is designed to prevent damage to property and loss of life. The cylinder is easy to install and operate, and it requires minimal maintenance. Guangzhou Xingjin Fire Equipment Co.,Ltd. provides online technical support to customers who purchase the FM200 Cylinder to ensure that the product is used effectively. The cylinders are transported in plywood outer boxes with bubble bags or paper to ensure that they reach the customers in perfect condition.

Customization:

We prioritize safety above all else, so you can trust that our Gaseous Fire Cylinder has been designed with safety in mind. Our cylinders are easy to install and come with an electromagnetic starting mode. We also take care in packaging and transport, using a plywood outer box with bubble bags or paper to ensure your cylinder arrives in perfect condition.

Packing and Shipping:

Product Packaging:

The FM200 Cylinder product will be securely packaged in a sturdy cardboard box with appropriate padding to prevent any damage during transportation. The cylinder will be sealed with a protective cap to prevent any leakage or damage.

Shipping:

The FM200 Cylinder product will be shipped via a reliable carrier service with tracking information provided to the customer. Shipping times may vary depending on the destination. Please ensure that someone is available to receive and sign for the product upon delivery.

FAQ:

Q: What is the brand name of this FM200 Cylinder product?

A: The brand name of this FM200 Cylinder product is Guangzhou Xingjin Fire Equipment Co.,Ltd.

Q: How many models of FM200 Cylinder are available?

A: There are seven models of FM200 Cylinder available, which are 40L, 70L, 90L, 100L, 120L, 150L, and 180L.

Q: Where is this FM200 Cylinder product manufactured?

A: This FM200 Cylinder product is manufactured in Guangzhou, Guangdong, China.

Q: What is the FM200 gas used in this product?

A: The FM200 gas used in this product is heptafluoropropane (HFP).

Q: What is the operating pressure range of this FM200 Cylinder product?

A: The operating pressure range of this FM200 Cylinder product is 2.5-5.0 MPa.

Previous article: